DIAGNOSIS OF WASTEWATER TREATMENT SYSTEM OF MANTA

Main Article Content

Giselle Velasco T.
Jorge Moncayo S.
David Chuquer S.

Abstract

A diagnosis of the removal efficiency of pollutants was made in the wastewater treatment plant (WWTP) of the city of Manta. The plant receives on average a volume of 30798 m3d-1 of wastewater. To that end, physicochemical analyses were carried out in the different stages of the treatment process. The results showed removal efficiencies of BOD5 of 51 % and COD of 56 %. These values, when compared with other WWTPs of the same type, indicate a poor removal of organic matter. Regarding the discharge effluent system, it was found that the COD, BOD5, Kjeldahl Nitrogen and Total Solids parameters exceed the maximum permissible limits of the Ecuadorian regulations. In conclusion, it was shown that the system requires maintenance, especially at the facultative lagoons, since it is the main responsible stage to reduce the global efficiency of pollutants removal.

Downloads

Download data is not yet available.

Article Details

Section
Cientific papers

References

Cárdenas, C., Jaeger, C., H., V., Perruolo, T., Yabroudi, S., López, F., . . . Castejón, O. (2005). Evaluación de unidades que conforman la planta de tratamiento de aguas residuales de Maracaibo sur. Revista Técnica de la Facultad de Ingeniería. Universidad del Zulia, 28(2), 97-109.

Cruz, L., Alayón-Torres, W., & Monsegny, C. (2000). Metodología para la selección de régimen de flujo en lagunas de estabilización. Revista Ingeniería e Investigación, 46, 14-19.

El diario. (16 de marzo de 2016). Eldiario.ec. Obtenido de Ciudad: Incienso contra malos olores: http://www.eldiario.ec/noticias-manabi-ecuador/386954-incienso-contramalos-olores/

El Sharkawi, F., El Sebaie, O., Hossam, A., & Abdel Kerim, G. (1995). Evaluation of Daqahla wastewater treatment plant, aerated lagoon and ponds system. Water Science and Technology, 32(11), 111-119.

Espinosa, M., von Sperling, M., & Verbyla, M. (2017). Perfomance evaluation of 388 full-scale waste stabilization pond system with seven different configurations. Water Science and Technology, 75(4), 916-927.

González, C., & González, H. (2016). Evaluación química y microbiológica de la playa de “Los Esteros” en la ciudad de Manta. La Granja: Revista de Ciencias de la vida, 23(1), 47-52.

Grady, L., Daigger, G., Love, N., & Filipe, C. (2011). Biological Wastewater Treatment (3. ed.). Boca Raton: CRC Press.

Hernández, F., & Zambrano, E. (2007). Inicio, duración y término de la estación lluviosa en cinco localidades de la costa ecuatoriana. Acta oceánica del pacífico, 14(1), 7-11.

Ho, L., Van Echelpoel, W., & Goethals, P. (2017). Design of waste stabilization pond systems: A review. Water Research, 123, 236-248.

Oliveira, S., & von-Sperling, M. (2010). Assesment of clasical surface organic loading design equations based on actual perfomance of primary and secondary facultative ponds. Water Science and Technology, 61(4), 971-977.

Pearson, H., Mara, D., Cawley, L., Arridge, H., & Silva, S. (1996). The performance of an innovative tropical experimental waste stabilisation pond system operating at high organic loadings. Water Science and Technology, 33(7), 63-73.

Pescod, M. (1996). The role and limitations of anaerobic pond systems. Water Science & Technology, 33(7), 11-21.

Registro Oficial. (13 de 02 de 2015). Edición especial No. 270 de 13 de febrero de 2015. Acuerdo ministerial No. 028: Sustitúyase el Libro VI del Texto Unificado de Legislación Secundaria. Quito, Pichincha, Ecuador: Registro Oficial.

Sato, T., Qadir, M., Yamamoto, S., Endo, T., & Zahoor, A. (2013). Global, regional, and country level need for data on wastewater generation, treatment, and use. Agricultural Water Management, 130, 1– 13.

SENPLADES. (2014). Agua potable y alcantarillado para erradicar la pobreza en el Ecuador. Quito: Secretaría Nacional de Planificacion y Desarrollo.

Velasco, G. (2018). Trabajo de investigacion para la obtención del título profesional de Químico. Evaluación de la eficiencia en la remoción de materia orgánica en una planta de tratamiento de aguas residuales en la ciudad de Manta. Universidad Central del Ecuador, Quito, Ecuador.

Von-Sterling, M., & Chenircharo, C. (2005). Biological Wastewater Treatment in Warm Climate Regions, (Vol.1). London: IWA Publishings.

Most read articles by the same author(s)